Welcome: Hunan Intelligent Applications Tecgnology CO.,ltd.-HNIAT.com
Language: Chinese ∷  English

Smart test

Digital circuit power integrity test system configuration and key performance indicators

High-speed digital circuit power integrity measurement has always been a difficult problem. Previously, most R&D units and companies did not measure these power integrity parameters. However, as the digital signal rate continues to increase, especially after it reaches the order of magnitude above 10Gbps, the measurement of power integrity has become one of the key test items. As a result, customers have been constantly inquiring about test solutions for power integrity recently, so now the configuration and key performance indicators of the power integrity test system are sorted out as follows.
1. Power integrity test system configuration:
DSO90254AE5061B(Opt: 005,3L5)N2873A(x2)1250-1250(x2),15442A85033E11667L8120-1840(x4)16201A(Opt:001),16195B16092A,16192A(16192A/B/C/D, 16197A according to your needs), 16047E
2. Key performance indicators of power integrity test system:
Ripple test capability: 3mv (PP) Impedance test capability: 1m ohm---50K ohm Frequency range: 5Hz--3GHz Basic test accuracy: +-2% SMD device test capability: Frequency DC--3GHz pin device test capability : Frequency DC-110MHz DC bias range: 0--+-40VDC
3. Test functions realized by the power integrity test system:
Power ripple measurement DC-DC converter loop gain (amplitude and phase) measurement PDN (power distribution network) milliohm impedance measurement filter capacitor/bypass capacitor/magnetic beads and other devices used in power distribution network impedance and parameters measuring

CONTACT US

Contact: Manager Xu

Phone: 13907330718

Tel: 0731-22222718

Email: hniatcom@163.com

Add: Room 603, 6th Floor, Shifting Room, No. 2, Orbit Zhigu, No. 79 Liancheng Road, Shifeng District, Zhuzhou City, Hunan Province

Scan the qr codeClose
the qr code